Search results for "atomic mass"
showing 10 items of 103 documents
Quartz resonators for penning traps toward mass spectrometry on the heaviest ions
2020
We report on cyclotron frequency measurements on trapped 206,207Pb+ ions by means of the non-destructive Fourier-transform ion-cyclotron-resonance technique at room temperature. In a proof-of-principle experiment using a quartz crystal instead of a coil as a resonator, we have alternately carried out cyclotron frequency measurements for 206Pb+ and 207Pb+ with the sideband coupling method to obtain 21 cyclotron-frequency ratios with a statistical uncertainty of 6 × 10−7. The mean frequency ratio R¯ deviates by about 2σ from the value deduced from the masses reported in the latest Atomic Mass Evaluation. We anticipate that this shift is due to the ion–ion interaction between the simultaneousl…
On-line commissioning of SHIPTRAP
2006
Abstract The on-line commissioning of the Penning-trap mass spectrometer SHIPTRAP was successfully completed with a mass measurement of holmium and erbium radionuclides produced at SHIP. A large fraction of contaminant ions created in the stopping cell was identified to originate from the buffer-gas supply system. Using a liquid nitrogen cold trap they were reduced to a tolerable amount and mass measurements of Er 147 , Er 148 , and Ho 147 with relative uncertainties of about 1 × 1 0 − 6 were performed.
Mass spectroscopic analysis of excimer laser ablated material from human corneal tissue.
1988
The clinical feasibility of photorefractive keratectomy depends on the surface structure of the ablated cornea. Two factors that influence the remodeled surface are the homogeneity of the energy distribution and the properties of the laser source (energy and wavelength). Currently, the homogeneity of the beam is difficult to control. The second factor, laser source properties, was the focus of this study. We investigated the effect of laser wavelength and energy by analyzing the reaction products of photoablation. We monitored the fragments produced by UV-laser ablation of human corneas using mass spectroscopy in the range of 0 to 100 atomic mass units. At 248 nm (KrF), average photon energ…
Measurement of the cosmic ray composition at the knee with the SPASE-2/AMANDA-B10 detectors
2004
The mass composition of high-energy cosmic rays at energies above 1015 eV can provide crucial information for the understanding of their origin. Air showers were measured simultaneously with the SPASE-2 air shower array and the AMANDA-B10 Cherenkov telescope at the South Pole. This combination has the advantage to sample almost all high-energy shower muons and is thus a new approach to the determination of the cosmic ray composition. The change in the cosmic ray mass composition was measured versus existing data from direct measurements at low energies. Our data show an increase of the mean log atomic mass 〈lnA〉 by about 0.8 between 500 TeV and 5 PeV. This trend of an increasing mass throug…
Proton-neutron pairing correlations in the self-conjugate nucleus 42Sc
2021
Collinear laser spectroscopy of the N=Z=21 self-conjugate nucleus 42Sc has been performed at the JYFL IGISOL IV facility in order to determine the change in nuclear mean-square charge radius between the Iπ=0+ ground state and the Iπ=7+ isomer via the measurement of the 42g,42mSc isomer shift. New multi-configurational Dirac-Fock calculations for the atomic mass shift and field shift factors have enabled a recalibration of the charge radii of the 42−46Sc isotopes which were measured previously. While consistent with the treatment of proton-neutron, proton-proton and neutron-neutron pairing on an equal footing, the reduction in size for the isomer is observed to be of a significantly larger m…
Precision experiments on exotic nuclei at IGISOL
2006
Abstract Cooling and trapping techniques of low-energy radioactive ion beams of refractory elements employed at the IGISOL facility are presented with emphasis on high-precision measurements of the ground state properties of exotic nuclei. The impact of the new generation Paul and Penning traps on mass measurements of short-lived nuclei is discussed with examples on precision measurements of masses of super-allowed beta emitters and neutron-rich nuclei. As a new concept the trap-assisted spectroscopy of radioactive ions is presented with applications in collinear laser spectroscopy, decay spectroscopy of isobarically purified sources and in nuclear cross-section measurements by ion counting.
Ion traps in nuclear physics—Recent results and achievements
2016
Abstract Ion traps offer a way to determine nuclear binding energies through atomic mass measurements with a high accuracy and they are routinely used to provide isotopically or even isomerically pure beams of short-living ions for post-trap decay spectroscopy experiments. In this review, different ion-trapping techniques and progresses in recent nuclear physics experiments employing low-energy ion traps are discussed. The main focus in this review is on the benefit of recent high accuracy mass measurements to solve some key problems in physics related to nuclear structure, nuclear astrophysics as well as neutrinos. Also, several cases of decay spectroscopy experiments utilizing trap-purifi…
Precision studies in traps: Measurement of fundamental constants and tests of fundamental theories
2003
Experiments on single atomic particles confined in Penning ion traps have contributed significantly to the improvements of fundamental constants and to tests of the theory of Quantum Electrodynamics for free and bound electrons. The most precise value of the fine structure constant as well as the electron mass have been derived from trap experiments. Numerous atomic masses of interest for fundamental questions have been determined with precisions of 10 � 9 or below. Further progress is envisaged in the near future.
Ion traps in nuclear physics : recent results and achievements
2016
Ion traps offer a way to determine nuclear binding energies through atomic mass measurements with a high accuracy and they are routinely used to provide isotopically or even isomerically pure beams of short-living ions for post-trap decay spectroscopy experiments. In this review, different ion-trapping techniques and progresses in recent nuclear physics experiments employing low-energy ion traps are discussed. The main focus in this review is on the benefit of recent high accuracy mass measurements to solve some key problems in physics related to nuclear structure, nuclear astrophysics as well as neutrinos. Also, several cases of decay spectroscopy experiments utilizing trap-purified ion sa…
Exploring the mass surface near the rare-earth abundance peak via precision mass measurements at JYFLTRAP
2019
The JYFLTRAP double Penning trap at the Ion Guide Isotope Separator On-Line (IGISOL) facility has been used to measure the atomic masses of 13 neutron-rich rare-earth isotopes. Eight of the nuclides, $^{161}$Pm, $^{163}$Sm, $^{164,165}$Eu, $^{167}$Gd, and $^{165,167,168}$Tb, were measured for the first time. The systematics of the mass surface has been studied via one- and two-neutron separation energies as well as neutron pairing-gap and shell-gap energies. The proton-neutron pairing strength has also been investigated. The impact of the new mass values on the astrophysical rapid neutron capture process has been studied. The calculated abundance distribution results in a better agreement w…